Support

PM5 firmware compatibility

Most ErgFuse features work on any PM5 that the app can identify and connect to. Firmware differences mainly affect programmed Solo and Multi-Erg workouts that use an open rest between intervals.

Last updated: October 2026

At a glance

  • Team Goal

    Works on all supported PM5s

    Team Goal uses Just Row, Just Ride or Just Ski. There are no programmed rest intervals and no Continue screen, so the open-rest firmware differences below do not apply.

  • Solo or Multi-Erg without open rest

    Works normally

    A single distance, calorie or time target—and intervals with a fixed rest—do not depend on automatic Continue. The specific open-rest interval issue does not apply.

  • Solo or Multi-Erg with open rest

    Firmware dependent

    An open rest is used when you leave an erg for a movement or another machine and return later. The firmware version determines whether ErgFuse can send Continue and whether the PM5 reports correct interval data after the rest.

Find your PM5 version

On the PM5, open:

More Options→Utilities→Product ID

On the current PM5 menu, Product ID is one step further, under More Utilities.

Read the number next to Firmware Version. It is the top line on that screen.

Example

262.067

262 = the PM5 version shown in the tables below

.067 = the firmware build

When ErgFuse is connected on your device (phone, tablet), the Machines screen shows this same version and build.

What is an open rest?

An open rest has no fixed duration. ErgFuse uses it when a workout includes a movement or another erg between two intervals on the same PM5. Concept2 calls this an undefined rest.

  1. 500 m RowErg
  2. 10 pull-ups
  3. 500 m RowErg

What happens at Continue?

After an interval with open rest, the PM5 waits before starting its next programmed interval.

On supported firmware, ErgFuse detects that you have resumed work and sends Continue to the PM5 automatically.

On other firmware versions, the PM5 shows Continue and you press it on the monitor yourself. The ErgFuse workout remains active, but the next PM5 interval does not start until Continue is accepted.

The PM5 allows an open rest of up to 10 minutes. Begin the next interval before that limit.

Interval data after an open rest

On affected PM5 firmware, the monitor can report incorrect interval data after the first open rest. Concept2 fixed this in build .062 for the firmware series that received that build.

Build .062 is the minimum build containing this fix, not the newest firmware. When a newer build is available for your PM5 series, install the latest available version.

This issue does not affect Team Goal because Team Goal does not use programmed intervals with open rest.

It also does not apply to a normal fixed-distance, fixed-calorie or fixed-time workout without open rest.

Check your machine

Find the version shown on your PM5 and match it to the correct machine below. The table tells you whether ErgFuse sends Continue automatically and what to do about open-rest interval data.

A higher PM5 version can belong to a later firmware series. Continue was added at a different version in each series, so a higher number does not always mean ErgFuse sends Continue.

RowErg

  • v1–v29

    After open rest
    Press Continue on the PM5
    Interval-data fix
    No .062 release in this series
    Recommended action
    Use the latest available firmware for this PM5
  • v30–v99

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    No .062 release in this series
    Recommended action
    Use the latest available firmware for this PM5
  • v150–v166

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v167–v199

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v200–v205

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v206–v299

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v450–v499

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware

SkiErg

  • v500–v549

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v700–v730

    After open rest
    Press Continue on the PM5
    Interval-data fix
    No .062 release in this series
    Recommended action
    Use the latest available firmware for this PM5
  • v731–v799

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    No .062 release in this series
    Recommended action
    Use the latest available firmware for this PM5
  • v850–v868

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v869–v899

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v900–v905

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v906–v949

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v950–v999

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware

BikeErg

  • v300–v326

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v327–v349

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v350–v355

    After open rest
    Press Continue on the PM5
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v356–v399

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v400–v449

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware
  • v550–v599

    After open rest
    ErgFuse sends Continue
    Interval-data fix
    Build .062 or newer
    Recommended action
    Update recommendedUpdate to the latest available firmware

Update your PM5

ErgFuse does not install PM5 firmware. Update the monitor with Concept2's official tools.

  • ErgData

    The easiest option for PM5s that support wireless firmware updates.

  • Concept2 Utility

    Use a Windows or Mac computer and a USB connection when ErgData cannot update the monitor wirelessly.

Updating to the latest firmware is recommended even when your current version already works with ErgFuse, because Concept2 also ships Bluetooth, reconnect, display and workout fixes.

If your version is not listed

If your PM5 version is not listed, update it to the latest available firmware first. Some older or unusual firmware ranges do not report enough machine information for ErgFuse to identify them reliably.

If the version is still not listed after updating, contact ErgFuse Support and include:

  • the machine type
  • the complete firmware version
  • the PM5 serial number
  • a photo of the Product ID screen

Technical note: machine identification

ErgFuse reads the machine from the PM5 when the monitor reports it. Some older monitors leave that out, and ErgFuse then uses the firmware series to tell a RowErg, SkiErg, and BikeErg apart. Versions 650–699 and 800–849 sit between those series. If a monitor in one of those ranges also omits the machine type, ErgFuse cannot connect.

Contact ErgFuse Support

Email support@ergfuse.app with your machine, the complete firmware version, the PM5 serial number, and a photo of the Product ID screen.

support@ergfuse.app